Pressure testing before sealing quantifies total leakage. Every leak point located and sealed with correct materials. Post-sealing pressure test documents the improvement. Every service guaranteed.
Your energy bills are higher than they should be for the amount of heating and cooling your home requires in Paragould. Certain rooms will not reach the right temperature regardless of how long the HVAC runs in Paragould, AR. You have had the equipment checked and it is working correctly in Paragould. If the equipment is fine but the home is not comfortable and the bills are high, the problem is almost certainly in the distribution system in Paragould, AR. Specifically, in duct leaks that are allowing conditioned air to escape into unconditioned attic or crawl space before it reaches the rooms you are paying to heat and cool in Paragould.
Duct leakage happens at every unsealed joint between duct sections, at every branch takeoff from the trunk line, at every register boot connection in the walls and ceilings, and at the connections where the duct system meets the air handler in Paragould, AR. The Department of Energy estimates that typical residential duct systems lose 20 to 30 percent of conditioned air through leakage in Paragould. For a home spending $200 per month on heating and cooling, that is $40 to $60 per month escaping through duct leaks to the attic or crawl space in Paragould, AR.
MBM Air Duct Cleaning finds and seals duct leaks throughout Paragould, AR in Paragould. Pressure testing before sealing to quantify the total leakage in Paragould, AR. Systematic identification of every specific leak point through the accessible system in Paragould. Correct sealant materials applied to every leak point in Paragould, AR. Post-sealing pressure testing to document the improvement with measured numbers in Paragould. And a guarantee on every sealing service in Paragould, AR. Call now for same-day scheduling in Paragould.
Standard duct tape uses a rubber-based adhesive that performs at room temperature but dries and loses adhesion when repeatedly exposed to the temperature extremes that duct systems experience during HVAC operation in Paragould. A supply duct carrying cold conditioned air through a 130-degree summer attic cycles through extreme temperatures with every cooling cycle in Paragould, AR. Standard duct tape adhesive is not formulated for this cycling and fails within a few seasons in Paragould. Mastic sealant remains flexible after curing and maintains its seal through years of thermal cycling in Paragould, AR. UL 181-rated foil tape maintains adhesion for 20 years or more in normal duct system conditions in Paragould.
Every connection between duct sections is a potential leak point in Paragould, AR. In most residential installations, these joints were mechanically fastened without sealant during installation in Paragould. Over years of thermal cycling that expands and contracts the ductwork with every HVAC cycle, even joints that were initially sealed with standard duct tape have failed as the tape dried and lost adhesion in Paragould, AR.
Branch takeoffs split conditioned air from the main trunk line into the individual branch runs serving each room in Paragould. They have multiple edges and angles that create significant potential leak area if not correctly sealed in Paragould, AR. Branch takeoff leaks are among the largest individual leak points in typical residential duct systems in Paragould.
The register boot connects the branch duct run to the wall, ceiling, or floor opening where the supply register mounts in Paragould, AR. The connection between the flexible duct and the boot collar and the connection between the boot and the surrounding framing are both common significant leak points in Paragould. Conditioned air escaping at the boot level leaks into the wall or ceiling cavity rather than through the register into the room in Paragould, AR.
Systems sealed with standard duct tape develop leakage as the tape dries, cracks, and loses adhesion from temperature cycling in Paragould. Standard duct tape on duct joints typically fails within three to five seasons of thermal cycling in Paragould, AR. Joints that were sealed with standard tape appear sealed when first applied and are open to leakage again within a few years in Paragould.
Supply duct leakage between the trunk line and the registers means rooms furthest from the air handler receive less conditioned air than they were designed to receive in Paragould. The conditioned air that leaks out before reaching the register does not reach the room in Paragould, AR. Rooms at the end of long duct runs with multiple leak points along the way receive the cumulative effect of all those leaks in Paragould. The room that is always too hot in summer and too cold in winter is often at the end of a duct run with multiple unsealed joints in Paragould, AR.
Return duct leaks draw air from the surrounding unconditioned space into the return airstream in Paragould. A return duct leak in an attic draws hot, dusty attic air into the air handler in summer in Paragould, AR. A return duct leak in a crawl space draws crawl space air including moisture, mold spores, and soil particulate into the system in Paragould. This unconditioned air bypasses the filter and is distributed throughout the home in Paragould, AR.
MBM Air Duct Cleaning performs a duct pressure test before any sealing begins in Paragould, AR. A calibrated fan is connected to the duct system and pressurized to a standard test pressure in Paragould. The measured airflow represents the total leakage rate and provides the baseline for comparing with the post-sealing result in Paragould, AR.
With the system pressurized, MBM technicians work through the accessible duct system to locate every specific leak point in Paragould. Every branch takeoff. Every duct joint. Every register boot connection. Every plenum seam and air handler connection in Paragould, AR. Every identified leak point is marked for sealing in Paragould.
Mastic sealant for most duct joint and connection applications in Paragould, AR. UL 181-rated foil tape for specific sheet metal seam applications in Paragould. The correct material for the specific application in Paragould, AR.
MBM systematically seals every identified leak point in the accessible duct system in Paragould. Mastic applied at the correct thickness to cover the full joint gap and bond to the duct surfaces on both sides in Paragould, AR. Every identified leak point addressed before the post-sealing pressure test in Paragould.
After all identified leak points are sealed, MBM repeats the pressure test to measure the post-sealing leakage rate in Paragould, AR. The before and after measurements quantify the leakage reduction achieved by the sealing in Paragould. Documented evidence of the result provided to the homeowner in Paragould, AR.
Mastic is a water-based sealant specifically formulated for duct system applications in Paragould, AR. It remains flexible after curing, maintaining its seal through the thermal cycling that duct systems experience in Paragould. It does not dry out, crack, or lose adhesion from temperature cycling the way standard duct tape does in Paragould, AR.
UL 181-rated foil tape is tested and rated specifically for HVAC duct applications in Paragould. Unlike standard duct tape, it maintains its adhesion through the temperature cycling of duct system operation in Paragould, AR. Appropriate for specific sheet metal seam applications in Paragould.
Standard silver duct tape is not rated for duct system applications in Paragould, AR. Its rubber-based adhesive dries and loses adhesion from temperature cycling in Paragould. MBM Air Duct Cleaning never uses standard duct tape for duct sealing work in Paragould, AR.
MBM performs pressure testing before and after every duct sealing service in Paragould, AR. The before and after measurements document the leakage reduction achieved in Paragould. Documented improvement, not assumed improvement in Paragould, AR.
MBM seals every identified leak point in the accessible duct system in Paragould. Not a representative sample. Not the most obvious points only in Paragould, AR. Every identified leak point in Paragould.
Mastic sealant and UL 181-rated foil tape that maintain their effectiveness through the thermal cycling of long-term HVAC operation in Paragould, AR. Never standard duct tape in Paragould.
Every MBM Air Duct Cleaning duct sealing service is guaranteed in Paragould. If the sealing does not produce the expected improvement within the guarantee period, we return and address it at no additional charge in Paragould, AR.
All pricing confirmed upfront before work begins in Paragould. No surprises in Paragould, AR.
A sealing service that reduces leakage by 15 to 20 percentage points returns that proportional energy cost reduction on every subsequent energy bill in Paragould, AR. For a home spending $200 per month on heating and cooling, a 15 percent leakage reduction saves approximately $30 per month in Paragould. A sealing service costing $500 to $1,000 pays for itself in energy savings within 18 to 36 months in most cases in Paragould, AR. Every month after payback is net return on the investment in Paragould.
Call now for same-day scheduling in Paragould.
Call Now — (888) 216-9551Homes, condos, apartments in Paragould, AR
Full north-side coverage in Paragould, AR
All south-side communities in Paragould
East-end homes and properties in Paragould, AR
Full west-side coverage in Paragould
Call to confirm availability in Paragould, AR
Duct leakage pays for conditioned air that heats and cools your attic and crawl space instead of your living spaces every month in Paragould. MBM Air Duct Cleaning quantifies the leakage with pressure testing, locates every specific leak point, seals every accessible leak with correct materials, confirms the improvement with post-sealing testing, and guarantees every service in Paragould, AR. Call now for same-day scheduling in Paragould.
Call Now — (888) 216-9551