Pressure testing before sealing quantifies total leakage. Every leak point located and sealed with correct materials. Post-sealing pressure test documents the improvement. Every service guaranteed.
Your energy bills are higher than they should be for the amount of heating and cooling your home requires in New Bern. Certain rooms will not reach the right temperature regardless of how long the HVAC runs in New Bern, NC. You have had the equipment checked and it is working correctly in New Bern. If the equipment is fine but the home is not comfortable and the bills are high, the problem is almost certainly in the distribution system in New Bern, NC. Specifically, in duct leaks that are allowing conditioned air to escape into unconditioned attic or crawl space before it reaches the rooms you are paying to heat and cool in New Bern.
Duct leakage happens at every unsealed joint between duct sections, at every branch takeoff from the trunk line, at every register boot connection in the walls and ceilings, and at the connections where the duct system meets the air handler in New Bern, NC. The Department of Energy estimates that typical residential duct systems lose 20 to 30 percent of conditioned air through leakage in New Bern. For a home spending $200 per month on heating and cooling, that is $40 to $60 per month escaping through duct leaks to the attic or crawl space in New Bern, NC.
MBM Air Duct Cleaning finds and seals duct leaks throughout New Bern, NC in New Bern. Pressure testing before sealing to quantify the total leakage in New Bern, NC. Systematic identification of every specific leak point through the accessible system in New Bern. Correct sealant materials applied to every leak point in New Bern, NC. Post-sealing pressure testing to document the improvement with measured numbers in New Bern. And a guarantee on every sealing service in New Bern, NC. Call now for same-day scheduling in New Bern.
Standard duct tape uses a rubber-based adhesive that performs at room temperature but dries and loses adhesion when repeatedly exposed to the temperature extremes that duct systems experience during HVAC operation in New Bern. A supply duct carrying cold conditioned air through a 130-degree summer attic cycles through extreme temperatures with every cooling cycle in New Bern, NC. Standard duct tape adhesive is not formulated for this cycling and fails within a few seasons in New Bern. Mastic sealant remains flexible after curing and maintains its seal through years of thermal cycling in New Bern, NC. UL 181-rated foil tape maintains adhesion for 20 years or more in normal duct system conditions in New Bern.
Every connection between duct sections is a potential leak point in New Bern, NC. In most residential installations, these joints were mechanically fastened without sealant during installation in New Bern. Over years of thermal cycling that expands and contracts the ductwork with every HVAC cycle, even joints that were initially sealed with standard duct tape have failed as the tape dried and lost adhesion in New Bern, NC.
Branch takeoffs split conditioned air from the main trunk line into the individual branch runs serving each room in New Bern. They have multiple edges and angles that create significant potential leak area if not correctly sealed in New Bern, NC. Branch takeoff leaks are among the largest individual leak points in typical residential duct systems in New Bern.
The register boot connects the branch duct run to the wall, ceiling, or floor opening where the supply register mounts in New Bern, NC. The connection between the flexible duct and the boot collar and the connection between the boot and the surrounding framing are both common significant leak points in New Bern. Conditioned air escaping at the boot level leaks into the wall or ceiling cavity rather than through the register into the room in New Bern, NC.
Systems sealed with standard duct tape develop leakage as the tape dries, cracks, and loses adhesion from temperature cycling in New Bern. Standard duct tape on duct joints typically fails within three to five seasons of thermal cycling in New Bern, NC. Joints that were sealed with standard tape appear sealed when first applied and are open to leakage again within a few years in New Bern.
Supply duct leakage between the trunk line and the registers means rooms furthest from the air handler receive less conditioned air than they were designed to receive in New Bern. The conditioned air that leaks out before reaching the register does not reach the room in New Bern, NC. Rooms at the end of long duct runs with multiple leak points along the way receive the cumulative effect of all those leaks in New Bern. The room that is always too hot in summer and too cold in winter is often at the end of a duct run with multiple unsealed joints in New Bern, NC.
Return duct leaks draw air from the surrounding unconditioned space into the return airstream in New Bern. A return duct leak in an attic draws hot, dusty attic air into the air handler in summer in New Bern, NC. A return duct leak in a crawl space draws crawl space air including moisture, mold spores, and soil particulate into the system in New Bern. This unconditioned air bypasses the filter and is distributed throughout the home in New Bern, NC.
MBM Air Duct Cleaning performs a duct pressure test before any sealing begins in New Bern, NC. A calibrated fan is connected to the duct system and pressurized to a standard test pressure in New Bern. The measured airflow represents the total leakage rate and provides the baseline for comparing with the post-sealing result in New Bern, NC.
With the system pressurized, MBM technicians work through the accessible duct system to locate every specific leak point in New Bern. Every branch takeoff. Every duct joint. Every register boot connection. Every plenum seam and air handler connection in New Bern, NC. Every identified leak point is marked for sealing in New Bern.
Mastic sealant for most duct joint and connection applications in New Bern, NC. UL 181-rated foil tape for specific sheet metal seam applications in New Bern. The correct material for the specific application in New Bern, NC.
MBM systematically seals every identified leak point in the accessible duct system in New Bern. Mastic applied at the correct thickness to cover the full joint gap and bond to the duct surfaces on both sides in New Bern, NC. Every identified leak point addressed before the post-sealing pressure test in New Bern.
After all identified leak points are sealed, MBM repeats the pressure test to measure the post-sealing leakage rate in New Bern, NC. The before and after measurements quantify the leakage reduction achieved by the sealing in New Bern. Documented evidence of the result provided to the homeowner in New Bern, NC.
Mastic is a water-based sealant specifically formulated for duct system applications in New Bern, NC. It remains flexible after curing, maintaining its seal through the thermal cycling that duct systems experience in New Bern. It does not dry out, crack, or lose adhesion from temperature cycling the way standard duct tape does in New Bern, NC.
UL 181-rated foil tape is tested and rated specifically for HVAC duct applications in New Bern. Unlike standard duct tape, it maintains its adhesion through the temperature cycling of duct system operation in New Bern, NC. Appropriate for specific sheet metal seam applications in New Bern.
Standard silver duct tape is not rated for duct system applications in New Bern, NC. Its rubber-based adhesive dries and loses adhesion from temperature cycling in New Bern. MBM Air Duct Cleaning never uses standard duct tape for duct sealing work in New Bern, NC.
MBM performs pressure testing before and after every duct sealing service in New Bern, NC. The before and after measurements document the leakage reduction achieved in New Bern. Documented improvement, not assumed improvement in New Bern, NC.
MBM seals every identified leak point in the accessible duct system in New Bern. Not a representative sample. Not the most obvious points only in New Bern, NC. Every identified leak point in New Bern.
Mastic sealant and UL 181-rated foil tape that maintain their effectiveness through the thermal cycling of long-term HVAC operation in New Bern, NC. Never standard duct tape in New Bern.
Every MBM Air Duct Cleaning duct sealing service is guaranteed in New Bern. If the sealing does not produce the expected improvement within the guarantee period, we return and address it at no additional charge in New Bern, NC.
All pricing confirmed upfront before work begins in New Bern. No surprises in New Bern, NC.
A sealing service that reduces leakage by 15 to 20 percentage points returns that proportional energy cost reduction on every subsequent energy bill in New Bern, NC. For a home spending $200 per month on heating and cooling, a 15 percent leakage reduction saves approximately $30 per month in New Bern. A sealing service costing $500 to $1,000 pays for itself in energy savings within 18 to 36 months in most cases in New Bern, NC. Every month after payback is net return on the investment in New Bern.
Call now for same-day scheduling in New Bern.
Call Now — (888) 216-9551Homes, condos, apartments in New Bern, NC
Full north-side coverage in New Bern, NC
All south-side communities in New Bern
East-end homes and properties in New Bern, NC
Full west-side coverage in New Bern
Call to confirm availability in New Bern, NC
Duct leakage pays for conditioned air that heats and cools your attic and crawl space instead of your living spaces every month in New Bern. MBM Air Duct Cleaning quantifies the leakage with pressure testing, locates every specific leak point, seals every accessible leak with correct materials, confirms the improvement with post-sealing testing, and guarantees every service in New Bern, NC. Call now for same-day scheduling in New Bern.
Call Now — (888) 216-9551